NON ASBESTOS JOINTING SHEETS |
|
FEROLITE NAM 39 STEEL GASKET
JOINTING SHEET
|
 |
|
Applications:
|
|
Water/oil resistant gasket material for light loading. Suitable
for low operating pressure, e.g. transformers, compressors and
apparatus. Also used for easily deformable components with low
surface pressure like valve covers and pans in internal
combustion engines. |
|
Supply Data: |
|
|
|
THICKNESS in mm |
:
|
0.30, 0.50, 0.75, 1.00, 1.50, 2.00, 3.00, 4.00. |
|
Sheet Size in mm |
: |
1500X1500, 1500x2000,1500X3000, 1500X4000, 1500X4500, 2000x3000. |
|
|
|
Note : Other sheet sizes & thickness upon request |
|
OPERATING CONDITION
|
:
|
Maximum internal pressure: 70
BAR
Maximum Temperature:
180°C
|
|
General data: |
|
|
|
Material Composition (Type of
fibres) |
: |
Aramid Fiber, Organic Fibre with Metal Gauge Centre. |
|
Binders |
: |
NBR |
|
Max.Peak Temp |
: |
250°C |
|
Max. Continuous Temp |
: |
180°C |
|
Max.Continuous Temp.with steam |
: |
120°C |
|
Max. Operating Pressure |
: |
70 bar |
|
Physical Properties: |
|
The following Information Applies to material Thickness 2.0 mm. |
| S.NO. |
PROERTIES |
TEST
METHOD |
UNIT |
SPECIFIED
VALUE |
|
1. |
DENSITY |
---------- |
gm / cm3 |
1.50 - 2.10 |
|
2. |
TENSILE STRENGTH |
|
|
|
|
(a) ACC to ASTM F152(ACROSS GRAIN) |
|
N/mm2 |
> 7 |
|
(b) ACC to DIN52910 (ACROSS GRAIN) |
|
N/mm2 |
> 5 |
|
3. |
COMPRESSIBILITY |
ASTM F36A |
% |
7 – 15 |
|
4. |
RECOVERY |
ASTM F36A |
% |
> 40 |
|
5. |
FLUID ABSORPTION |
|
|
|
|
(a) IN ASTM OIL NO. 3 |
ASTM F 146 |
|
|
|
INCREASE IN MASS |
|
% |
< 15 |
|
INCREASE IN
THICKNESS |
|
% |
< 10 |
|
(b) IN FUEL B |
ASTM F 146 |
|
|
|
INCREASE IN MASS |
|
% |
< 10 |
|
INCREASE IN
THICKNESS |
|
% |
< 10 |
|
(c) IN WATER/ANTIFREEZE |
ASTM F 146 |
|
|
|
INCREASE IN MASS |
|
% |
< 15 |
|
INCREASE IN
THICKNESS |
|
% |
< 7 |
|
6. |
IGNITION LOSS |
DIN 52911 |
% |
< 40 |
 NOTE:
All data quoted above
are based on years of experience in production & operation of
sealing elements, in view of the wide variety of possible
installation & operating conditions one can not draw final
conclusion in all application cases regarding the behavior in gasket
joint. The data may not therefore, be used to support any warranty
claims.
Should you have any doubts about the
choice of gasket material, please refer to us. Our engineering cell
will be happy to assist you.
|